ATE

Nuclear Power Plant & Heavy Ion Accelerator Test System And Solution

Heavy Ion Accelerator Test System And Solution

Heavy Ion Accelerator Test System And Solution

Bipolar Power Supply for Coil Control of Heavy Ion Accelerator

Heavy ion accelerator is a large-scale research equipment that accelerates ions of all elements on earth which are heavier than hydrogen and helium at close to light speed. Accelerated particles collide with a material, converting it into smaller femto units of material, and discovering many new isotopes. This new isotopes are used in various fields such as new material development, medical application, etc. We supply bipolar type power supply for coil control to Research centers, researchers and test centers related Heavy ion accelerator and help to develop new material.

TPT15-10B

Model No. TP20-10B
Key Features

  • Bipolar output in electronic switch type
  • +/- 0~20V / 10A
  • 10mV/10mA Resolution
  • Ripple & noise(10Vrms)
  • Accuracy
  • R11; Programming(0.1%+30mV/0.1%+30mA)
  • R11; Readback(0.1%+20mV/0.1%+30mA)
  • Protection(OVP, OCP)
  • Remote Interface(RS-232C, RS-485)
  • Dimensions : 70mm(W) x 125.5mm(H) x 450mm(D)
  • We can supply other capacity besides this model, Please contact us for further discussion.
opmn

Model No. MX60-200
Key Features

  • Bipolar output in mechanical relay contact type
  • +/- 0~18V/1A
  • 1mV/100uA Resolution
  • Ripple & noise(2mVp-p/2mArms)
  • Accuracy
  • R11; Programming(0.05% + 10mV/0.15% + 5mA)
  • R11; Readback(0.05% + 5mV/0.08% + 2mA)
  • Protection(OVP, OCP)
  • Remote Interface(RS-232C, GPIB)
  • Dimensions : 213mm(W) x 133mm(H) x 394mm(D)
MX-Series

Model No. MX60-200
Key Features

  • AC INPUT : 380V/400V ±10% 50/60Hz 3Phase 3Line
  • DC OUTPUT : 30V, 50V, 60V, 80V, 100V, 150V, 200V, 300V, 400V, 500V, 600V/10A~1500A,10V, 20V, 800V, 1000V, 1250V, 1500V
  • Power Factor 0.95@Full Load
  • Programming/ReadBack Accuracy : 0.1%(Volt), 0.4%(Curr)
  • OVP, OCP, OTP, FAN Fail, PMP, VA Balance, V-Sens Error, AC Input Fail, Rectifier Fail Protection
  • Size : 426mm(W) x 132.5mm(H) x 660mm(D)
  • Ripple & Noise : 20mVrms, 60mVpp(@30V)
  • Volt Rise/Fall : 30ms(@Full Load)
  • Transient Response Time : 0.75%/1ms
  • Efficiency : 88%(@Full Load)

System Integration Diagram

Nuclear Integration

Application

  • Research centers related Heavy ion accelerator
  • Manufacturers of Heavy ion accelerator
  • Acceleration test of Heavy ion accelerator
  • Electronic coil valve test

Software

iv-cedm-test
  • Voltage/Current setting Independently for each channels, Multi-channel configuration can be made through additional consultation
  • Data acquisition such as voltage, current, and temperature etc.
  • PLC and control signal can be interworked
  • Various protection such as Over voltage protection(V), Under voltage protection(V), Over current protection(A), Over temperature protection(℃),
    Channel data in data logger(Option), ΔV /+ΔV protection(V), +ΔI /-ΔI protection(A) etc
  • Position and Acceleration Control
  • Graph implementation and data saving for each channel
  • Functions can be added according to user requirements

Main Customer

Main Customer