Products

OPE-Q Series Linear Programmable DC Power Supply

Economical type, 4 Channels (2 variable output, 2 fixed output), Non-Isolated type

OPE-Q Series is high performance programmable DC power supply with RS232C or RS485 interface based on SCPI (Standard Commands for Programmable Instruments) protocol and the combination of bench-top and system features in these power supplies provides versatile solutions for your design and test requirements in the industrial fields, R&D institute center and education fields.

Dimension

Half of 19inch x 2U size : 213mm(W) x 88mm(H) x 362mm(D), RS-232C interface
Inquiry
  • 1 LCD (Volt/Curr and Message Display Module) 13 5V/2A (Fixed) Over Load Protection Lamp
    2 Encoder S/W for changing Volt/Curr 14 15V/1A (Fixed) Over Load Protection Lamp
    3 I/O or LOCAL Key 15 5V/2A (Fixed) + Output Terminal
    4 Output ON/OFF Key 16 5V/2A (Fixed) – Output Terminal
    5 Volt/Curr select or Limit Display Key 17 15V/1A (Fixed) + Output Terminal
    6 OUTPUT Channel Select or Tracking Key 18 15V/1A (Fixed) – Output Terminal
    7 Volt/Curr Cursor or menu change Key 19 P1 + Output terminal (Positive Output)
    8 Volt/Curr Cursor or menu change Key 20 P1&P2 Output COM Terminal
    9 P1 Constant Current mode indicate Lamp 21 P2 – Output terminal (Negative Output)
    10 P2 Constant Current mode indicate Lamp 22 Earth GND Terminal
    11 P1,P2 channel Tracking mode indicate Lamp 23 Main Power ON/OFF Switch
    12 Remote Interface mode indicate Lamp    
    • 3-Digit Display Resolution
    • 16×2 Big-Character Type LCD Display
    • CV/CC Mode
    • Output ON/OFF Function
    • Tracking Mode Function(Control 2 output at the same time)
    • 2 variable output & 2 fixed output
    • Memory Save and Recall(Up to 5 operation states)
    • Half of 19inch(213mm) wide x 2U size(Less than 300W)
    • RS-232C communication interface(RS-485 is optional)
    • TRACKING MODE

      Two channels can be controlled at once.

      If single channel power supply was supplied for each producer when it comes to your company’s mass production system, replace it with the power supply in two channels that supports our company’s tracking mode! There is no need to set up two channels’ voltage and current which is cumbersome. Instead, pressing simply one button, the tracking mode button can set up two channels in the same way using only one setting for the voltage, current and all the functions.

    • STORE & RECALL

      Save and Recall Voltage and Current set by user easily.

      OPE Series can store and recall the voltage and current set by user. Even when a user is not an engineer, the user can use it easily for the production, product inspection, reliability test etc., with the Store and Recall function that set up and stored in advance.

    Line-Up and Specification

    Model
    Parameter

    OPE-185Q

    OPE-303Q

    OPE-305Q

    OPE-503Q

    Output rating

    0~±18V, 0~5A 2CH
    Fixed output 2CH

    0~±30V, 0~3A 2CH
    Fixed output 2CH

    0~±30V, 0~5A 2CH
    Fixed output 2CH

    0~±50V, 0~3A 2CH
    Fixed output 2CH

    Resolution

    Programming/Readback

    ≤ 6mV / ≤ 1.5mA

    ≤ 7.5mV / ≤ 1mA

    ≤ 7.5mV / ≤ 1.5mA

    ≤ 15mV / ≤ 1mA

    Display Meter

    100mV / 10mA

    100mV / 10mA

    100mV / 10mA

    100mV / 10mA

    Programming Accuracy (@25 ±5)±(%of output + offset)

    Voltage

    0.2% + 120mV

    0.2% + 200mV

    0.2% + 200mV

    0.2% + 300mV

    Current

    0.2% + 25mA

    0.2% + 15mA

    0.2% + 25mA

    0.2% + 15mA

    Read-back Accuracy (@25 ±5)±(%of output + offset)

    Voltage

    0.2% + 120mV

    0.2% + 200mV

    0.2% + 200mV

    0.2% + 300mV

    Current

    0.2% + 25mA

    0.2% + 15mA

    0.2% + 25mA

    0.2% + 15mA

    Ripple & Noise

    ≤ 2mVp-p, ≤ 2mArms

    ≤ 2mVp-p, ≤ 2mArms

    ≤ 2mVp-p, ≤ 2mArms

    ≤ 3mVp-p, ≤ 2mArms

    Voltage Programming Speed(No load)

    Rising time

    ≤ 40㎳

    ≤ 40㎳

    ≤ 40㎳

    ≤ 70㎳

    Falling time

    ≤1.2s

    ≤1.2s

    ≤1.2s

    ≤1.5s

     

     

    Model
    Parameter

    OPE-801Q

    OPE-1001Q

    OPE-1201Q

    Output rating

    0~±80V, 0~2A 2CH
    Fixed output 2CH

    0~±100V, 0~1A 2CH
    Fixed output 2CH

    0~±120V, 0~1A 2CH
    Fixed output 2CH

    Resolution

    Programming/Readback

    ≤ 30mV / ≤ 0.8mA

    ≤ 40mV / ≤ 0.5mA

    ≤ 50mV / ≤ 0.5mA

    Display Meter

    100mV / 10mA

    1V / 10mA

    1V / 10mA

    Programming Accuracy (@25 ±5)±(%of output + offset)

    Voltage

    0.3% + 500mV

    0.5% + 800mV

    0.5% + 900mV

    Current

    0.2% + 15mA

    0.2% + 15mA

    0.2% + 15mA

    Read-back Accuracy (@25 ±5)±(%of output + offset)

    Voltage

    0.3% + 500mV

    0.5% + 800mV

    0.5% + 900mV

    Current

    0.2% + 15mA

    0.2% + 15mA

    0.2% + 15mA

    Ripple & Noise

    ≤ 6mVp-p, ≤ 2mArms

    ≤ 0.01%mVrms, ≤ 2mArms

    ≤ 0.01%mVrms, ≤ 2mArms

    Voltage Programming Speed(No load)

    Rising time

    ≤ 70㎳

    ≤ 70㎳

    ≤ 70㎳

    Falling time

    ≤1.5s

    ≤1.5s

    ≤1.5s

    Common Details 2 Fixed output channels ( 5V/2A, 15V/1A )
    Half of 19inch x 2U size: 213mm(W) x 88mm(H) x 362mm(D), RS-232C interface
    • Options

      • RS-232C cable
      • RS-485 cable
      • OVP, OCP(Remote Communication control only)
      • Output ON/OFF signal control
      • Analog Programming(Vout & Iout voltage programming) & Monitoring(Output Voltage & Current Monitoring) by 0~5V or 0~10V, Isolated type
      • AC Power Cord(Other type)
      • AC Input 110V ± 10%, 230V± 10%, 50~60Hz
      • Rack Mount Support(Bracket and Shelf)
    • Accessories

      • AC Power Cord(Type F)
      • Operating Manual(QR Code)
      • Demo software program(QR Code)
      • Banana to Alligator DC Output Cables(+,-)